65
Parameter Name & Functions Default Unit
Setting
Range
Control
Mode
Communication
Address
RS232 RS485
Sn217
Analog Speed Command offset adjust
0 mV
-10000
10000
S 534H 0211H
The offset amount can be adjusted by this parameter.
Sn218
Analog speed command limited
Rate
rpm x
1.02
rpm
100
4500
S C11H 0212H
Setting Sn218 for limit the highest speed command of
analog input.