Chapter 4 Software Index
4-59
Auto_run mode Description
1. The inverter is controlled by the keypad,to use Auto_run function, please set as below:
Example: 100-03=0 or 00-04=0, refer to P4-20/ P4-24
201-00(S1)=22(Auto_run)
3Set parameter as(A)(B)(C), Auto_run function come true.
4 When S1 close, Auto_run function is enable, press RUN/STOP key on keypad offer
Run or stop instruction.
2. The inverter is controlled by the external terminals,to use Auto_run function , please set as below:
Example: 1 00-03/00-04=1 (external terminals)
2 00-11=0(Operation modes of external terminals : FWD/STOP-REV/STOP)
Note: this section 00-11 do not set 1 or 2.
3 01-00(S1)=0 (FWD/STOP)
4 01-01(S2)=22(Auto_run)
5 Set parameter as(A)(B)(C) Auto_run function come true
6 When S2 close, Auto_run function is enable, turn S1 ON/OFF offer Run or stop
instruction.
3. The inverter is controlled by communication,to use Auto_run function , please set is as below:
Example: 1 01-00(S1)=22(Auto_run Mode)
2Set parameter as(A)(B)(C) , function come true
When S1 close, Auto_run function is enable, communication offer Run or stop instruction.