6-5
Note:
The setting value of the counter could be a constant or the present value of the timer,
counter,analog input A1~A8.
※Foer I1~gF, Input terminal: I1~IC (I1~I12), Output terminal: Q1~Q8, Expansion Input
Terminal: X1~XC (X1~X12), Expansion Output Terminal: Y1~YF (Y1~Y12), Counter: C1~CF
(C1~C15), Timer: T1~TF (T1~T15), RTC Comparator: R1~RF (R1~R15) , Analog Comparator:
G1~GF (G1~G15),Auxiliary Terminal:M1~MF(M1~M15).
The upper case (I1) is Contact ‘a while the lower (i1) case is Contact ‘b’.
The set value of counter can be modified via communication module as MODBUS,
PROFIBUS, DEVICENET, TCP/IP.
(1) Counter Mode 1
Note:
When Run user program, current value shall be initialized to be 0 or preset value.(If up
counter, then 0; if down counter, then preset value)