Chapter 3: Menu reference > Option 13 Start Auto Access Test
28 Challenger10 Administrators Manual
The following programming is required:
The inputs to be tested must be included in access tests (input test types 1, 2,
4, or 5). Camera count inputs must be assigned input test type 0 “No Testing”.
The access test time programmed by the installer must be sufficient for you to
test all the required inputs (default time is 15 minutes).
The RAS beeper sounds continuously during the testing time or until you exit this
option.
Access Test, NEXT For Untested
"0"-Cancel:
From the initial screen, press [NEXT] to display an untested input, test the input
by unsealing and then sealing it, and press [NEXT] to display the next untested
input. Repeat until all inputs have been tested.
If [NEXT] is selected to display any untested inputs, the LCD screen displays the
first input number and its assigned name. If you see only numbers and no
names, refer to Displaying input nameson page 8.
Untested Access On 4, Office PIR
NEXT or ENTER
Alternatively, press [ENTER] to proceed to the camera test or the Test
Completed/Not Completed display (as applicable).
Untested Access On 2, Camera 1
NEXT or ENTER
Inputs that are programmed as a camera input types (and assigned to area 1)
are also tested.
All Cameras Have Tested Successfully
Press ENTER
When all inputs that are programmed to be tested (including 0 inputs) during the
access test have been tested, or the time allowed for access test has expired,
the test will automatically cease and the display will indicate if the test is
completed or not completed.
Test Completed
Press ENTER
Press [ENTER] to exit this option.