Commands Listed in Alphabetical Order
Examples
BUS:B1:I2C:AD
DRESS:RWINCLUDE ON
includes the read/write bit in the
address.
BUS:B1:I2C:A
DDRESS:RWINCLUDE?
might return
BUS:B1:I2C:ADDRESS:RWINCLUDE 0 indicating the read/write bit is not
included in the address.
BUS:B<x>:I
2C{:CLOCk|:SCLk}:SOUrce
This command specifies the SCLK source for the I2C bus.
Conditions
This command requires a DPO4EMBD application module for 4000 series
models, and an MDO3EMBD application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:I2C{:CLOCk|:SCLk}:SOUrce {CH1|CH2|CH3| CH4|
D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11| D12|D13|D14|D15}
BUS:B<x>:I2C{:CLOCk|:SCLk}:SOUrce?
Arguments
CH1–CH4 specifies an analog channel as the SCLK source waveform.
D0–D15 specifies a digital channel as the SCLK source waveform.
(MSO/MDO4000/B models only as well as MDO3000 and MDO400C models
with option MDO3MSO or MDO4MSO installed.)
BUS:B<x>:I2C{:DATa|:SDAta}:SOUrce
Specifies the SDATA source for the I2C bus.
Conditions
This command requires a DPO4EMBD application module for 4000 series
models, and an MDO3EMBD application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:I2C{:DATa|:SDAta}:SOUrce {CH1|CH2|CH3| CH4|
D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11| D12|D13|D14|D15}
BUS:B<x>:I2C{:DATa|:SDAta}:SOUrce?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-181