Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4AUTOMAX application module for 4000 series
models, and MDO3FLEX application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:FLEXray:SOUrce
{CH1|CH2|CH3|CH4|D0|D1|D2|D3|D4|D5|D6| D7|D8|D9|D10
|D11|D12|D13|D14|D15}
BUS:B<x>:FLEXray:SOUrce?
Arguments
CH1–CH4 specifies an analog channel as the source waveform.
D0-D15 specifies a digital channel as the source waveform.
(MSO/MDO4000/B models only as well as MDO3000 and MDO400C models
with option MDO3MSO or MDO4MSO installed.)
Examples
BUS:B1:FLEXRAY:SOURCE CH4 sets the source waveform to channel 4.
BUS:B1:FLEXRAY:SOURCE? might return BUS:B1:FLEXRAY:SOURCE CH1
indicating the source waveform is channel 1.
BUS:B<x>:I2C:ADDRess:RWINClude
Sets and returns whether the read/write bit is included in the address.
Conditions
This command requires a DPO4EMBD application module for 4000 series
models, and an MDO3EMBD application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:I2C:ADDRess:RWINClude {<NR1>|OFF|ON}
BUS:B<x>:I2C:ADDRess:RWINClude?
Arguments
<NR1> = 0 does not include the read/write bit in the addess; any other value
includes the read/write bit in the address.
OFF does not include the read/write bit in the address.
ON includes the read/write bit in the address.
2-180 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual