Commands Listed in Alphabetical Order
Group
Bus
Syntax
BUS:B<x>:FLEXray:CHannel {A|B}
BUS:B<x>:FLEXray:CHannel?
Arguments
A sets the FlexRay ID format to channel A.
B sets the FlexRay ID format to channel B.
Examples
BUS:B1:FLEXRAY:CHANNEL B sets the ID format to channel B.
BUS:B1:FLEXRAY:CHANNEL? might return BUS:B1:FLEXRAY:CHANNEL A
indicating that the ID format is channel A.
BUS:B<x>:FLEXray:SIGnal
Specifies the FlexRay bus standard.
Conditions
This command requires a DPO4AUTOMAX application module for 4000 series
models, and MDO3FLEX application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:FLEXray:SIGnal {BDIFFBP|BM|TXRX}
BUS:B<x>:FLEXray:SIGnal?
Arguments
BDIFFBP sets the FlexRay standard to BDIFFBP.
BM sets the FlexRay standard to BM.
TXRX sets the FlexRay standard to TXRX.
Examples
BUS:B1:FLEXRAY:SIGNAL BM sets the FlexRay bus standard to BM.
BUS:B1:FLEXRAY:SIGNAL? might return BUS:B1:F LEXRAY:SIGNAL
BDIFFBP
indicating the FlexRay standard is BDIFFBP.
BUS:B<x>:FLEXray:SOUrce
Specifies the FlexRay bus source waveform.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-179