Commands Listed in Alphabetical Order
Examples
DIAG:RESULT:F
LAG?
might return DIAG:RESULT:FLAG PASS.
DIAg:RESUlt:LOG? (Query Only)
Returns the internal results log from the last self-test sequence execution. The
list contain
s all modules and module interfaces that were tested along with the
pass/fail status of each.
Group
Calibration and Diagnostic
Syntax
DIAg:RESUlt:LOG?
Related Commands
DIAg:RESUlt:FLAg?
Returns
<QString> in the following format:
<Status>--<Module name>[,<Status>--<Module name>..]
Examples
DIAG:RESULT:LOG? might return :DIAG:RESULT:LOG "NOT
RUN--CPU,PASS--DISPLAY,NOT RUN--FPANEL,NOT RUN--IO,NOT
RUN--ACQ,NOT RUN--RO M,NOT RUN- -APPKEY"
DIAg:SELect (No Query Form)
This command specifies which of the diagnostic groups will be tested when the
DIAg:STATE EXECute command is run.
Group
Calibration and Diagnostic
Syntax
DIAg:SELect
{ALL|APPKey|CPU|DISplay|FPAnel|IO|ROM| ACQ|RF|AFG}
Arguments
ALL runs all diagnostic groups.
APPKey runs just the application key diagnostic group.
CPU runs just the CPU diagnostic group.
DISplay runs just the display circuit diagnostic group.
FPAnel runs just the front panel diagnostic group.
2-286 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Other manuals for Tektronix MDO4000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO4000B Series and is the answer not in the manual?

Tektronix MDO4000B Series Specifications

General IconGeneral
BrandTektronix
ModelMDO4000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals