Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:QUALity:FREQREFerence {VOLTage|CURRent}
POWer:QUALity:FREQREFerence?
Arguments
VOLTage sets voltage as the power quality frequency reference source.
CURRent sets current as the power quality frequency reference source.
Examples
POWER:QUALITY:FREQREFERENCE CURRent sets current as the power quality
frequency reference source.
POWER:QUALITY:FREQREFERENCE? might return
:POWER:QUALITY:FREQREFERENCE VOLTAGE indicating that the power quality
frequency reference source is set to Voltage.
POWer:QUALity:FREQuency? (Query Only)
Returns the frequency measurement.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:QUALity:FREQuency?
Examples
POWER:QUALITY:FREQUENCY? might return :POWER:QUALITY:FR EQUENCY
60
indicating that the frequency is set to 60 Hz.
POWer:QUALity:ICRESTfactor? (Query Only)
Returns the current crest factor measurement.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.