Commands Listed in Alphabetical Order
tosearchontot
he hexadecimal value XX08, assuming the qualifier is set to
LESSthan, MOREthan, EQual, UNEQ ual, LESSEQual or MOREEQual.
SEARCH:SEARC
H1:TRIGger:A:BUS:B1:ETHERnet:MAC{:LENg th|
:TYPe}:VALue “XXXXXXXX00001000”
sets the lower limit of the range to the
hexadecimal value XX08, assuming the qualifier is set to
INrange or OUTrange.
SEARCH:SEA
RCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:?HIVALue
When the Ethernet search condition is set to MACLENgth,andthe
qualifier is set to either
INrange or OUTrange, this command
specifies
the upper data value of this range. (Use the command
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ET HERnet:
MAC{:LENgth|:TYPe}:VALue
to set the lower limit of the range.)
The default is all X’s (don’t care).
SEARCH<x> is the search number, which is
always 1, and
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ET HERnet:MAC{:LENgth|:
TYPe}:?HIVALue <QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ET HERnet:MAC{:LENgth|:
TYPe}:?HIVALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:
TYPe}:VALue
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:QUALifier
Arguments
QString is a quoted string of up to 16 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:ETHERn et:MAC{:LENgth| :TYPe}
:HIVALue
“XXXXXXXX00001000” sets the upper limit of the range to the
hexadecimal value XX08 (when the search condition is set to
MACLENgth,and
the qualifier is set to
INrange or OUTr
ange).
2-642 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual