Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:DATa:OFFSet
<NR1>
SEARCH:SEARCH<
x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFS et?
Arguments
<NR1> is the data offset in bytes. A byte offset of -1 signifies don't care, and no
byte offset is used. The instrument will search or match any byte value that fits.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:DATA:OFFSET 10 sets
the FLEXRAY data offset to 10 bytes.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRA Y:DATA:OFFSET? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY :DATA:OFFSET 0
indicating the offset is set to 0 bytes.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier
Thiscommandspecifiesthequalifier(<,>,=,<=,>=,not=,inrange,
out of range) to use when searching on the FlexRay bus data field.
The search condition needs to be set to ID or IDANDDATA (using
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:DATa:QUALifier
{LESSthan|MOREthan|EQual|UNEQual|LESSE Qual|MOREEQual|
INrange|OUTrange}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FL EXray:DATa:QUALifier?
2-652 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual