Commands Listed in Alphabetical Order
Syntax
SEARCH:SEARCH
<x>:TRIGger:A:BUS:B<x>:MIL1553B:DATa:PAR ity
{0|1|X|ZERo|ONE|NOCARE|OFF|ON}
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:MIL1553B:DATa: PARity?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue
Arguments
0
1
X
sets the valu
e to X (“don’t care”) which is the default.
ZERO sets the value to 0.
ONE sets the value to 1.
NOCARE sets the value to X (“don’t care”) which is the default.
OFF sets the value to 0.
ON sets the value to 1.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:DATa:PARity 1 sets the
dataparitybittobeusedinaMIL-STD-1553bussearchto1.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:DATa:PARity? might
return 0, indicating that the data parity bit to be used in a MIL-STD-1553 bus
search is set to 0.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue
When the MIL-STD-1553 bus search condition is set to DATa, this command
specifies the data binary pattern to be used in the search. This is a 16-bit field.
SEARCH<x> is the search number, which is always 1, and B<x>