Commands Listed in Alphabetical Order
Arguments
<QString> with
in the range 0000000 to 1111111 (00 hex to 7F hex).
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:USB:AD DRESS:VALUE “0001000”
sets the binary address to 0001000 (08 hex).
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:USB:AD DRESS:VALUE? might return
:SEARCH:SEARCH1:TRIGGER:A:BUS:B1:USB:A DDRESS:VALUE “1000000”,
which indicates that the binary address is 100000 (40 hex).
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:CONDition
This command specifies the search condition for a USB search. SEARCH<x> is the
search number, which is always 1, and
B<x>
Conditions
This command requires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:US B:CONDition
{SYNC|RESET|SUSPEND|RESUME|EOP|TOKENPa cket|DATAPacket
|HANDSHAKEPacket|SPECIALPacket|ERRor}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:US B:CONDition?
Arguments
SYNC specifies to search for a Sync field of a packet.
RESET specifies to search for a reset condition.
SUSPEND specifies to search for a suspend condition.
RESUME specifies to search for a resume condition.
EOP specifies to search for an end-of-packet signal.
TOKENPacket specifies to search for a token packet.
DATAPacket specifies to search for a data packet
HANDSHAKEPacket specifies to search for a handshake packet.
SPECIALPacket specifies to search for a special status packet.
ERRor specifies to search for an error condition.
2-702 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual