Commands Listed in Alphabetical Order
Conditions
This command re
quires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:US B:ADDRess:HIVALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:US B:ADDRess:HIVALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:CONDition,
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:ADDRess:VALue
Arguments
<QString> within the range 0000000 to 1111111 (00 hex to 7F hex).
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:USB:AD DRESS:HIVALUE
“0001000”
sets the upper limit to binary 0001000 (08 hex).
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:USB:AD DRESS:HIVALUE? might
return
:SEARCH:SEARCH1:TRIGGER:A:BUS:B1:USB:ADDR ESS:HIVALUE
“1111111”
, which indicates that the upper limit is 1111111 (7F hex).
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:ADDRess:VALue
This command specifies the address value for the lower limit for inside-of-range
and outside-of-range qualifiers to be used in a USB search.
SEARCH<x> is the
search number, which is always 1, and
B<x>
Conditions
This command requires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:US B:ADDRess:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:US B:ADDRess:VALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:CONDition
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-701