Commands Listed in Alphabetical Order
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BU
S:B<x>:SPI:DATa{:MOSI|:OUT}:
VALue < bin>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SP I:DATa{:MOSI|:OUT}:
VALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SPI:CONDition
Arguments
<bin> is the data in binary format.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SPI:D
ATa:SIZe
ThiscommandspeciesthelengthofthedatastringtobeusedinanSPIsearch,
if the search condition is
MISO, MOSI,orMISOMOSI. SEARCH<x> is the search
number, which is always 1, and
B<x>
Conditions
This command requires a DPO4EMBD application module for DPO/MSO4000B
and MDO4000/Bmodels or MDO3EMBD application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SP I:DATa:SIZe <NR1>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SP I:DATa:SIZe?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SPI:CONDition
Arguments
<NR1> is the data string length in bytes.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:ADDRess:HIVALue
This command specifies the upper limit of the address string for the inside-of-range
and outside-of-range qualifiers to be used in aUSB search. Use the command
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:USB:ADDRess:VALue to set
the lower limit.
SEARCH<x> is the search number, which is always 1, and B<x>
2-700 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Other manuals for Tektronix MDO4000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO4000B Series and is the answer not in the manual?

Tektronix MDO4000B Series Specifications

General IconGeneral
BrandTektronix
ModelMDO4000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals