Commands Listed in Alphabetical Order
TRIGGER:A:BUS
:B1:USB:ADDRESS:VALUE?
might return
:TRIGGER:A:BUS:B1:USB:ADDRESS:VALUE “1000000”,which
indicates that the binary address is 100000 (40 hex).
TRIGger:A:B
US:B<x>:USB:CONDition
This command specifies the trigger condition for the USB trigger. B<x>
Conditions
This command requires the DPO4USB application module to be installed, except
for MDO3000 models, which require the MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:USB:CONDition
{SYNC|RESET|SUSPEND|RESUME|EOP|TOKENPa cket|DATAPacket
|HANDSHAKEPacket|SPECIALPacket|ERRor}
TRIGger:A:BUS:B<x>:USB:CONDition?
Arguments
SYNC indicates triggering on a Sync field of a packet.
RESET sets triggering on a reset condition.
SUSPEND setstriggeringonasuspendcondition.
RESUME sets triggering on a resume condition.
EOP indicates t
riggering on an end-of-packet signal.
TOKENPacket indicates triggering on a token packet.
DATAPacket indicates triggering on a data packet
HANDSHAKEPacket indicates triggering on a handshake packet.
SPECIALPacket indicates triggering on a special status packet.
ERRor indicates triggering on an error condition.
Examples
TRIGGER:A:BUS:B1:USB:CONDITION TOKENPACKET sets the trigger condition
to be a token packet.
TRIGGER:A:BUS:B1:USB:CONDITION? might return
:TRIGGER:A:BUS:B1:USB:CONDITION SYNC, which indicates that the trigger
condition is a sync field.
2-860 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual