Removal and Installation Procedures
SPG600 & SPG300 Sync Pulse Generators Service Manual 6-15
Front-Panel Assembly
1. Locate module to be removed: Locate the front-panel assembly in the locator
diagram SPG600 External modules, Figure 6-2, on page 6-8.
2. Orient instrument: Set the SPG600 so its bottom is down on the work surface
and its front is facing you.
3. Remove the front cover: See Figure 6-8.
a. Push and release the three snaps at the bottom of the front cover using a
flat-bladed screwdriver.
b. Grasp the front cover and pull it forward.
4. Remove the LCD module: See Figure 6-8.
a. Use a screwdriver with a #2 Phillips tip to remove the four screws securing
the LCD module to the chassis.
b. Unplug the cable from the A10 Main board.
5. Remove the A20 front-panel board: See Figure 6-8.
a. Use a screwdriver with a #2 Phillips tip to remove the two screws securing
the LCD module to the chassis.
b. Unplug the cable from the A10 Main board.
6. Reinstallation: Perform steps 3 through 5 in reverse order to reinstall the
front-panel assembly.

Table of Contents

Other manuals for Tektronix SPG3UP 01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix SPG3UP 01 and is the answer not in the manual?

Tektronix SPG3UP 01 Specifications

General IconGeneral
BrandTektronix
ModelSPG3UP 01
CategoryPulse Generator
LanguageEnglish

Related product manuals