Performance Verification
SPG600 & SPG300 Sync Pulse Generators Service Manual 4-7
11. Set the output signal format and genlock source of the sync pulse generator as
follows:
a. Press the CANCEL button to return the SYSTEM menu.
b. Press the up (
S) or down (T) arrow button to select CONFIGURATION.
c. Press the ENTER button to display the Configuration submenu.
d. Press the left (
W) or right (X) arrow button to select PAL.
e. Press the ENTER button.
f. Press the GENLOCK button to display the Genlock menu.
g. Press the up (
S) or down (T) arrow button to select GENLOCK
SOURCE.
h. Press the left (
W) or right (X) arrow button to select PAL Burst.
i. Press the ENTER button.
12. Verify that the vector display is locked and that the EXT.REF LED on the
sync pulse generator lights.
13. Press the left (
W) or right (X) arrow button to select NTSC Burst.
14. Press the ENTER button.
15. Verify that the vector display is unlocked.
16. Press the left (
W) or right (X) arrow button to select 625 SYNC.
17. Press the ENTER button.
18. Verify that the vector display is locked.
19. Change the signal format setting of the TV signal generator (AGL7 module) to
NTSC.
20. Change the sync pulse generator settings as follows:
a. Press the SYSTEM button to display the System menu.
b. Press the up (
S) or down (T) arrow button to select CONFIGURATION.
c. Press the ENTER button to display the Configuration submenu.
d. Press the left (
W) or right (X) arrow button to select NTSC.
e. Press the ENTER button.
f. Press the GENLOCK button to display the Genlock menu.