EasyManuals Logo

Tektronix SPG3UP 01 User Manual

Tektronix SPG3UP 01
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Operating Basics
SPG600 & SPG300 Sync Pulse Generators User Manual 2-5
SDI 3 and SDI 4
Serial digital black or serial digital test signal outputs (SPG600 Option 03 only).
By default, the SDI 3 connector outputs a serial digital black signal, and the SDI 4
connector outputs a serial digital test signal. Use the System menu to change the
output channel configuration.
AES 1+2, AES 3+4,
AES 5+6, and AES 7+8
AES/EBU serial digital audio outputs for channels 1 & 2, 3 & 4, 5 & 6, and 7 & 8
respectively (SPG600 only).
1+2/RIGHT and 3+4/LEFT
(XLR connector)
AES/EBU serial digital audio or analog audio outputs for channels 1 & 2 and
3 & 4 respectively. By default, these connectors output an AES/EBS serial digital
audio. Use the System menu to change the output configuration.
WORD CLK
48 kHz word clock signal output.

Table of Contents

Other manuals for Tektronix SPG3UP 01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix SPG3UP 01 and is the answer not in the manual?

Tektronix SPG3UP 01 Specifications

General IconGeneral
BrandTektronix
ModelSPG3UP 01
CategoryPulse Generator
LanguageEnglish

Related product manuals