Page #31 background image
Understanding Oscilloscope Functions
12
TDS1000/2000-Series Digital Oscilloscope User Manual
Setting Up the Oscilloscope
You should become familiar with three functions that you may use
often when operating your oscilloscope: Autoset, saving a setup, and
recalling a setup.
Using Autoset
The Autoset function obtains a stable waveform display for you. It
automatically adjusts the vertical scale, horizontal scale and trigger
settings. Autoset also displays several automatic measurem ents in the
graticule area, depending on the signal type.
Saving a Setup
The oscilloscope saves the current setup if you wait five seconds
after the last change before you power off the oscilloscope. The
oscilloscope recalls this setup the next time you apply power.
You can use the SAVE/RECALL Menu to permanently save up to ten
different setups.
Recalling a Setup
The oscilloscope can recall the last setup before power off, any of
your saved setups or the default set up. See page 175.

Table of Contents

Other manuals for Tektronix TDS2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS2024 and is the answer not in the manual?

Tektronix TDS2024 Specifications

General IconGeneral
Channels4
Bandwidth200 MHz
Sample Rate2 GS/s
Record Length2.5k points
Vertical Resolution8 bits
Vertical Sensitivity2 mV/div to 5 V/div
Timebase Range5 ns/div to 50 s/div
Display Resolution320 x 240 pixels
Math FunctionsAdd, Subtract, Multiply, Divide, FFT
Input CouplingAC, DC, GND
Trigger ModesAuto, Normal, Single
Trigger TypesEdge, Video, Pulse
ConnectivityUSB
Input Impedance1 MΩ
Maximum Input Voltage300 V
InterfaceUSB
Power Supply100 to 240 V
Dimensions326 mm x 158 mm x 124 mm