Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 319
Y specifies a normal waveform where one ASCII or binary data point is
transmitted for each point in the waveform record. Only y values are explicitly
transmitted. Absolute coordinates are given by:
X
n
= XZEro + XINcr (n–PT_Off)
Y
n
= YZEro + YMUlt (y
n
− YOFf)
ENV
specifies that the oscilloscope transmit the waveform as minimum and
maximum point pairs. Peak detect and envelope waveforms use an ENV format.
Only y values are explicitly transmitted. Absolute coordinates are given by:
X
n
= XZEro + XINcr (n–PT_Off)
Y
n
min
= YZEro + YMUlt (y
n
min
− YOFf)
Y
n
max
= YZEro + YMUlt (y
n
max
− YOFf)
WFMPRE:PT_FMT Y
sets the waveform data point format to Y.
WFMPRE:PT_FMT?
returns either Y or ENV.
WFMPre:PT_Off
The set form of this command is ignored. The query form always returns a 0, if
the waveform specified by DATA:SOUrce is on or displayed. If the waveform is
not displayed, the query form generates an error and returns event code 2244.
This command is listed for compatibility with other Tektronix oscilloscopes.
Waveform
WFMPre:PT_Off
WFMPre:PT_Off?
Arguments are ignored.
WFMPre:<wfm>:PT_Off
Arguments
Examples
Group
Syntax
Arguments
Related Commands

Table of Contents

Other manuals for Tektronix TDS3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS3000 Series and is the answer not in the manual?

Tektronix TDS3000 Series Specifications

General IconGeneral
BrandTektronix
ModelTDS3000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals