Command Descriptions
2-50
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
NOTE. If you set the acquisition system to single sequence, envelope mode, and
set the number of envelopes to infinity, the oscilloscope will envelope a maximum
of 513 acquisitions.
ACQUIRE:STOPAFTER RUNSTop
sets the oscilloscope to stop acquisition when the user presses the front-panel
RUN/STOP button.
ACQUIRE:STOPAFTER?
might return SEQUENCE.
ACQuire:MODe, ACQuire:STATE
ALIas
Turns command aliases on or off. This command is identical to the
ALIas:STATE command.
Alias
ALIas { OFF | ON | <NR1> }
ALIas?
OFF or <NR1> = 0 turns alias expansion off. If a defined alias label is sent when
ALIas is OFF, an execution error (102, “Syntax error: illegal use of alias-alias”)
will be generated.
ON or <NR1> ¸ 0 turns alias expansion on. When a defined alias is received, the
specified command sequence is substituted for the alias and executed.
ALIAS ON
turns the alias feature on.
ALIAS?
returns 1 when aliases are on.