Checking Gamut
Checking Luma Gamut
Luma limit thresholds can be congured for identifying luma exceeding threshold limits. They apply to both the incoming
SDI and to the arrowhead representation of the SDI input as a composite signal. By dening these levels in percent, they
automatically account for the presence or absence of setup. The thresholds are affected by your choice of set-up or no
set-up for the Arrowhead display.
1. Perform the Setup for Gamut Checks
procedure. Select Arrowh ead in step 5.
(See page 44.)
2. Compare the signal to display to
determine out of gamut luminance. Note
the following:
The adjustable thresholds are
indicated by the dark blue horizontal
graticule lines.
The thresholds are dened in terms
of percent of full scale.
The range for the Upper limit is 90%
to 108%.
The range to the Lower Limit is -6%
to +5%.
Another useful Arrowhead function is a measure of how well the active video signal is using the dynamic range of the video
channel. A properly adjusted signal should be centered in the arrowhead graticule and have transitions that approach
all the limits.
Waveform Monitors Quick Start User Manual 49

Table of Contents

Other manuals for Tektronix WFM6120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix WFM6120 and is the answer not in the manual?

Tektronix WFM6120 Specifications

General IconGeneral
BrandTektronix
ModelWFM6120
CategoryMonitor
LanguageEnglish

Related product manuals