R309 AT Commands
©2015 Telegesis (UK) Ltd - 50 - AT Command Manual (Rev 3.09)
Execute Command
AT+DMODE:<address>
Where <address> can be the remote node’s
EUI64, Network address or address table index
Note
Opening a serial link to end devices will result in
a limited data rate which depends on the polling
interval of the child.
In Data mode all prompts are disabled
Use on
All Devices
Response
SEQ:XX
OK
or
ERROR<errorcode>
Prompt
ACK:XX
or NACK:XX
<errorcode> represents the error code explained
in section 3 and XX is the sequence number of
the unicast.
Remote Prompt
DataMODE:<Network address>,<EUI64>
OPEN
Where <Network address> is the Network
address of the remote node and <EUI64> is its
EUI64.
Prompt
DataMODE:<Network
address>,<EUI64>,<errorcode>
[OPEN]
Where <Network address> is the Network
address of the remote node and <EUI64> is its
EUI64. Only if the errorcode equals 0 the data
mode will open
.
SW release
R302
Execute Command
+++
To leave data mode +++ must be entered at a
minimum of 500ms after the last character which
is to be transmitted to the remote node. In case
the data payload contains +++ it can be
transmitted safely as long as it is made sure no
more than 250ms pass between sending +++
and the previous character.
Use on
All Devices
Response
CLOSED
SW release
R302