R309 AT Commands
©2015 Telegesis (UK) Ltd - 57 - AT Command Manual (Rev 3.09)
+RDATAB – Send Binary Raw Data
AT+RDATAB:XX
Use on
All Devices
Notes
Can be useful to quickly exchange bulk data
with neighbouring node. The application needs
to handle addressing, error checking, retries and
acknowledgements.
End Devices do not receive raw data.
Raw data will only travel one hop.
Use with great care. Raw data messages are
not ZigBee-compliant and may even leak into
other PANs.
> <data being entered>
OK
or ERROR:<errorcode>
Parameters
XX ranging from 00 to 67 (hex)
After the ‘>’ prompt a number of XX characters
are expected to be entered. Up to 103 bytes of
data can be send to all nodes within reach
(direct neighbours)
The data is neither encrypted nor error checked.
No retries are made and no acknowledgement is
received.
<errorcode> represents the error code explained
in section 3.
RAW:snn,<data>
where snn is the RSSI, or
<data>
in case bit 9 of S0E is set. Displaying the data
can also be disabled by setting bit D of S0E.