R309 AT Commands
©2015 Telegesis (UK) Ltd - 77 - AT Command Manual (Rev 3.09)
Description
String containing the module’s order code and
firmware revision.
Operations
R LOCAL
R REMOTE
Storage
Non-Volatile
Parameters
ccc…ccc
Text string
Example
ETRX357 R309C
Factory Default
N/A
SW release
R300
Description
Defines the behaviour of the Device.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
Where XXXX represents a 16-bit hexadecimal
number.
Range
0000 to FFFF
Bit F: Set: Disable ‘>’ prompt when entering
binary data
Bit E: Set: Disable UCAST, MCAST, BCAST,
SCAST data
Bit D: Set: Disable RAW data
Bit C: Set: Disable SEQ prompt
Bit B: Set: Disable SINK prompt
Bit A: Set: Disable SR: prompt
Bit 9: Set: Disable RAW wrapper
Bit 8: Set: Disable NEWNODE prompt
Bit 7: Set: Disable NACK:XX prompt
Bit 6: Set: Disable ACK:XX
Bit 5: Set: Disable UCAST, MCAST, BCAST,
SCAST wrapper
Bit 4: Set: Disable LeftPAN prompt
Bit 3: Set: Disable JPAN prompt
Bit 2: Set: Disable PWRCHANGE:nn prompt
Bit 1: Set: Disable OK prompt
Bit 0: Set: Disable ERROR:XX prompt
Factory Default
0000
SW release
R300