R309 AT Commands
©2015 Telegesis (UK) Ltd - 73 - AT Command Manual (Rev 3.09)
Description
The parent nodes 16-bit Network address.
Operations
R LOCAL
R REMOTE
Note
The return value is undefined for nodes without
parents (coordinators and nodes that are not
joined to a network). For an FFD, S07 is the ID
of the node via which the local node joined the
PAN
Storage
Non-Volatile
Parameters
<Network address>
Range
0000-FFF7
Factory Default
n/a
SW release
R300
Description
The network key which can be written using the
password. The default password for R3xx is
password”.
Operations
W LOCAL
W REMOTE
Write operation
ATS08=<key>:<password>
ATREMS:<address>,08=<key>:<password>
Becomes effective
Only when establishing a PAN
Storage
Non Volatile
Range
From 0 to 2
128
-1
The 128-bit AES network key in hexadecimal
representation (32 characters).
When set to all 0s (default) a random network
key is generated when establishing a PAN.
This key is transmitted to all joining nodes and
can be encrypted using the link key.
Factory Default
00000000000000000000000000000000
SW release
R300