R309 AT Commands
©2015 Telegesis (UK) Ltd - 72 - AT Command Manual (Rev 3.09)
The local node’s unique EUI64 identifier.
Operations
R LOCAL
R REMOTE
Storage
Non-Volatile
<EUI64>
Range
0000000000000000 – FFFFFFFFFFFFFFFF
Factory Default
<unique number>
S05 – Local 16-Bit Network address
The local node’s 16-bit Network address.
Note
Reading this register while not associated with a
network will result in an undefined return value.
Operations
R LOCAL
R REMOTE
Storage
Non-Volatile
<Network address>
Range
0000-FFF7
Factory Default
n/a
The parent node’s unique EUI64 identifier.
Note
The return value is undefined for nodes without
parents (coordinators and nodes that are not
joined to a network). For an FFD, S06 is the ID
of the node via which the local node joined the
PAN
Operations
R LOCAL
R REMOTE
Storage
Non-Volatile
<EUI64>
Range
0000000000000000 – FFFFFFFFFFFFFFFF
Factory Default
n/a