User Manual CXE85X
59300464 Rev.005
9.12.2013 22(44)
IP address: This is a static IP address of the CXE85x and should be consistent
with the LAN IP and subnet settings. The address is taken into use when IP
address configuration mode is set to manual. Factory default setting is
169.254.1.1.
Netmask: The subnet mask for the IP interface. Should be configured
according the LAN settings. Taken into use when IP address configuration
mode is set to manual. Factory default setting is 255.255.0.0.
Gateway: All packets that have a destination address not belonging to
CXE85x’s subnet are sent to this address. Should be configured according the
LAN settings. Factory default setting is 0.0.0.0.
Trap receiver settings
Status: Use this value to enable/disable trap sending to this address.
IP address: IP address of remote SNMP trap receiver.
Port: Port number of remote SNMP trap receiver listening to incoming SNMP
traps. Default port is 162.
Community: SNMP community name for remote trap receiver. Default
community is public”.
External control
RF output port features an “open collector output” for purposes of alarming or
control signal output. It can be used to control external equipment, for example
Ethernet switch powering.
Activation timeout: The user can adjust the unicast timeout in seconds
(0 - 65535). If CXE85x does not receive any unicast packets over the specified
time the control port is activated. Value 0 means that control port functionality is
disabled. Factory default setting is 0 s (disabled).
Output activation length: Length of time that the control port is activated. If the
control port activation time is set to 0 s, the control port is always active. Factory
default setting is 2 s.