User Manual CXE85X
59300464 Rev.005
9.12.2013 40(44)
CLI commands
? / help
Print list of commands, a brief explanation follows
each command.
quit / exit Exit telnet connection
reset [comm | all]
Without parameters performs software reset, with
parameters resets communication settings or all
settings to factory default. Disconnects telnet
Prints unit status. For details take a look for Viewer
pages “Status”, “Communication” and “Properties”.
Example:
mac: 00905004E8F2
hw: A1.0
sw: 1.1.3
optical1: -26.7 dBm LOLO(5)
optical2: -26.7 dBm LOLO(5) [CXE851: N/A]
rflevel: -4 dBm Lo(4)
temperature: 43 C Nominal(1)
Prints units identification data. For details take a look
for Viewer page “Properties”.
Example:
description: TELESTE CXE852 OPTICAL NODE
serno: XK00051211
vendor: Teleste Corporation
http://www.teleste.com
name: CXE852 @ Salmra
location: Eiger
contact: www.teleste.com
lat: 60.12340 N
lon: 22.45670 E
uptime: 5630
days: 99
Prints measurements and alarm statuses. For details
take a look for Viewer page “Status”.
Example:
optical1: -26.7 dBm LOLO(5)
optical2: -26.7 dBm LOLO(5) [CXE851: N/A]
rflevel: -4 dBm Lo(4)
temperature: 43 C Nominal(1)
Prints RF settings. For details take a look for Viewer
page “Settings”.
Example:
input: auto [CXE851: 1]
adjmode: sw
gain: 0
slope: off
omi: 4.0