User Manual CXE85X
59300464 Rev.005
9.12.2013 41(44)
comm
Prints communication settings. For details take a
look for Viewer page “Communication”.
Example:
ethernet: 100 M FULL DUPLEX
mac: 00905004E8F2
dhcp: on (10.2.12.68 255.255.252.0
10.2.15.254)
ip: 169.254.1.1 255.255.0.0 0.0.0.0
traps: enabled
trapreceiver1: 0.0.0.0 disabled
trapreceiver2: 0.0.0.0 disabled
readcommunity: public
writecommunity: private
exttimeout: 0
Prints monitoring settings. For details take a look for
Viewer page “Monitoring”.
Example:
optical1 hihi 20 hi 10 lo -70 lolo -80
deadband 5
optical2 hihi 20 hi 10 lo -70 lolo -80
deadband 5 [CXE851: N/A]
rflevel hihi 250 hi 200 lo 0 lolo -200
deadband 20
temperature hihi 80 hi 75 lo -10 lolo -20
all
Same as "info" + "properties" + " rf" + "comm" +
"monitoring"
CXE85x parameters can be changed using the following read/write commands
RF parameters (For details take a look for Viewer page “Settings”.)
input [auto | 1 | 2]
Optical input selection: automatic / manual1 /
manual2. CXE851 always returns 1.
adjmode [hw | sw |
omi]
Adjustment mode: hardware / software-manual /
software-OMI
gain [VALUE] Gain: VALUE dB. Unit 1 dB.
slope [flat | middle |
high]
Slope: flat / middle / high
omi [VALUE]
Transmitter OMI for software-OMI mode: VALUE %.
Unit 0.1 %.
targetlevel [VALUE]
Target output level for software-OMI mode: VALUE
dBµV. Unit 1 dBµV.
olc [on | off] OLC: on / off