User Manual CXE85X
59300464 Rev.005
9.12.2013 42(44)
Communication parameters (For details take a look for Viewer page
“Communication”.)
External control activation timeout: VALUE s. 0
disables external control.
External control activation length: VALUE s. 0
activates external control permanently.
Shows DHCP status and addresses.
Enables/disables DHCP. Disconnects telnet session.
Manual IP configuration: address, network mask,
default gateway. Disconnects telnet session.
SNMP write community
traps [on | off] Trap sending enabled / disabled
trapreceiver1
[IPADDR] | [on | off]
Trap receiver 1 IP address and enable/disable.
trapreceiver2
[IPADDR] | [on | off]
Trap receiver 2 IP address and enable/disable.
Monitoring parameters (For details take a look for Viewer page “Monitoring”.)
optical1 [enable] [hihi |
hi | lo | lolo |
deadband] [VALUE]
Optical input 1 power value, alarm limits, enabling
and deadband.
optical2 [enable] [hihi |
hi | lo | lolo |
deadband] [VALUE]
Optical input 2 power value, alarm limits, enabling
and deadband. CXE851 always all disabled.
rflevel [enable] [hihi | hi
| lo | lolo | deadband]
[VALUE]
RF output power value, alarm limits, enabling and
deadband.
temperature [enable]
[hihi | hi | lo | lolo |
deadband] [VALUE]
Temperature value, alarm limits, enabling and dead-
band.
-Identification parameters (For details take a look for Viewer page
“Properties”.)
name [TEXT] Unit alias name: TEXT, max. 60 chars
contact [TEXT]
Unit contact info: TEXT, max. 60 chars
Unit location: TEXT, max. 60 chars