Figure 1-9 Confidea G3 battery pack bottom side up
1.
Test button: Push to check the capacity and the status of the battery pack.
2.
Capacity and status indicator: Shows the capacity of the battery pack
3.
Clip: Locks/unlocks the battery pack in the wireless unit.
4.
Power LED: indicates that the charger is connected and powered.
5.
Charging LED: Indicates the charging status (in progress or completed) when the wall plug battery
charger is connected.
6.
Socket: to connect the charger plug.
Battery Charging And Handling
Charge the Confidea battery pack immediately on receipt.
Immediately recharge the battery pack when the remaining capacity drops below 20%. This
can be noticed when only LED1 (red) lights up on the battery pack (see section 8.5)
Empty battery packs must be charged within 30 days.
Do not leave an empty battery pack in a delegate unit.
Best practices for maximizing the lithium ion battery life is to keep the batteries in the charging
trays charging with proper ventilation between uses (i.e., charging in the CHC transport case
with the cover open)
The lifetime of a battery pack can be severely affected if it is completely drained. If a delegate
unit is put in storage or is not being used for a while, remove the battery pack and place it in the
charger.