EasyManua.ls Logo

Telpo TP-8S - Page 67

Default Icon
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TP-8/16/24/32/64S User Manual Version No.: V1.2
- 67 -
The parameter is only “3.5”, “7” or “0”, unit is dB.
Command to set compressed chip package cycle
codec_ep1> pktintvl {parameter}
The parameter is the package cycle, unit is ms. For example:
codec_ep1> pktintvl 20
Coding priority setting command
Interaction setting mode:
codec_ep1> priority
Only “priority” command is entered, the command line will inquire the priority that user is going to
set, as shown below:
Algorithm priorities:
[1] G.711A G.711U G.729 G.723.1
[2] G.711U G.711A G.723.1 G.729
[3] G.729 G.711A G.711U G.723.1
[4] G.729 G.723.1 G.711A G.711U
[5] G.723.1 G.711A G.711U G.729
[6] G.723.1 G.729 G.711A G.711U
Input your choice[1~6]:
At this time it is only allowed to enter numbers from choice [1~6]. Users are able to press “CtrlC”
or directly button enter key to get out of priority setting status if driven by the intention to give up
setting.
Non-interaction setting method
codec_ep1> priority {parameter}
The parameter is only chosen from [1~6], which stands for the sequences of six coding priorities under
interaction method.
Setting command of value of RFC2833 payload type
codec_ep1> rfc2833_pt {parameter}
The parameter ranges from 96 ~ 127.
Ring time setting command
codec_ep1> ring {parameter1} {parameter2}
Parameter 1 is “on time”, namely the ring duration time; parameter 2 is “off time”, namely the ring
interval time. The parameters for the both range from 065535, unit is ms.
Command of mute compressed switch setting
codec_ep1> sc {parameter}
The parameter is only “enable” or “disable”. Therein, “enable” means to open the mute compressing