EasyManua.ls Logo

Texas Instruments bq78350-R1

Texas Instruments bq78350-R1
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
www.ti.com
112
SLUUBD3DSeptember 2015Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
SLPAD (Bit 26): ADC Measurement in SLEEP mode
1 = Active
0 = Inactive
RSVD (Bit 25): Reserved. Do not use.
INIT (Bit 24): Initialization after full reset
1 = Active
0 = Inactive
SLEEPM (Bit 23): SLEEP mode
1 = Active
0 = Inactive
XL (Bit 22): 400-kHz SMBus mode
1 = Active
0 = Inactive
CAL_OFFSET (Bit 21): Calibration Output (raw CC offset data).
1 = Active when MAC OutputShortedCCADCCal() is sent and the raw shorted CC data for
calibration is available.
0 = When the raw shorted CC data for calibration is not available.
CAL (Bit 20): Calibration Output (raw ADC and CC)
1 = Active
0 = Inactive
RSVD (Bit 19): Reserved. Do not use.
AUTH (Bit 18): Authentication in progress
1 = Active
0 = Inactive
LED (Bit 17): LED Display
1 = LED display is on.
0 = LED display is off.
SDM (Bit 16): SHUTDOWN triggered via command
1 = Active
0 = Inactive
SLEEP (Bit 15): SLEEP mode conditions met
1 = Active
0 = Inactive
XCHG (Bit 14): Charging disabled
1 = Active
0 = Inactive
XDSG (Bit 13): Discharging disabled
1 = Active
0 = Inactive
PF (Bit 12): PERMANENT FAILURE mode status
1 = Active
0 = Inactive
SS (Bit 11): SAFETY mode status
1 = Active

Table of Contents