www.ti.com
0x55 ChargingStatus
139
SLUUBD3DSeptember 2015Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x54 OperationStatus() R R Block H4
0x00000
000
0xFFFF
FFFF
17.50 0x55 ChargingStatus
This command returns the ChargingStatus() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x55 ChargingStatus() R R Block H4
0x00000
000
0xFFFF
FFFF
17.51 0x56 GaugingStatus
This command returns the GaugingStatus() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x56 GaugingStatus() R R Block H4
0x00000
000
0xFFFF
FFFF
17.52 0x57 ManufacturingStatus
This command returns the ManufacturingStatus() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x57 ManufacturingStatus() R R Block H4
0x00000
000
0xFFFF
FFFF
17.53 0x58 AFEStatus
This command sets or gets the configuration of the companion AFE (address 0x00).
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x58 AFEStatus() R R Block H1 0x00 0xFF
17.54 0x59 AFEConfig
This read/write-block function sets or gets the configuration of the companion AFE (address 0x01 to
0x0B).
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x59 AFEConfig() R R String H4
17.55 0x5A AFEVCx
This command returns the cell voltage measurement data of the companion AFE (address 0x0C to 0x29)
on ManufacturerBlockAccess() or ManufacturerData().

Table of Contents

Other manuals for Texas Instruments bq78350-R1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments bq78350-R1 and is the answer not in the manual?

Texas Instruments bq78350-R1 Specifications

General IconGeneral
BrandTexas Instruments
Modelbq78350-R1
CategoryController
LanguageEnglish

Related product manuals