0x5B AFEData
www.ti.com
140
SLUUBD3DSeptember 2015Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x5A AFEVCx() R R String H4
17.56 0x5B AFEData
This command returns the system voltage, temperature, and current measurement data of the companion
AFE (address 0x2A to 0x33, 0x50, 0x51, and 0x59) on ManufacturerBlockAccess() or ManufacturerData().
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x5B AFEData() R R String H4
17.57 0x60 Lifetime Data Block 1
This command returns the first block of Lifetime data. For a description of returned data values, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x60 LifeTimeDataBlock1() R R Block
17.58 0x61 Lifetime Data Block 2
This command returns the second block of Lifetime data. For a description of returned data values, see
the ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x61 LifeTimeDataBlock2() R R Block
17.59 0x62 Lifetime Data Block 3
This command returns the third block of Lifetime data. For a description of returned data values, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x62 LifeTimeDataBlock3() R R Block
17.60 0x63 Lifetime Data Block 4
This command returns the third block of Lifetime data. For a description of returned data values, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x63 LifeTimeDataBlock4() R R Block
17.61 0x64 Lifetime Data Block 5
This command returns the third block of Lifetime data. For a description of returned data values, see the
ManufacturerAccess() version of the same command in Section 17.2.

Table of Contents

Other manuals for Texas Instruments bq78350-R1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments bq78350-R1 and is the answer not in the manual?

Texas Instruments bq78350-R1 Specifications

General IconGeneral
BrandTexas Instruments
Modelbq78350-R1
CategoryController
LanguageEnglish

Related product manuals