0x4C DynamicPower()
137
SLUUBD3D–September 2015–Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
SBS Cmd Mode Name Format Size in Bytes Min Max Default Unit
0x30
R
Reserved
Unsigned
Integer
2 0 65535 — mV
0x31 CellVoltage15
0x32 CellVoltage14
0x33 CellVoltage13
0x34 CellVoltage12
0x35 CellVoltage11
0x36 CellVoltage10
0x37 CellVoltage9
0x38 CellVoltage8
0x39 CellVoltage7
0x3A CellVoltage6
0x3B CellVoltage5
0x3C CellVoltage4
0x3D CellVoltage3
0x3E CellVoltage2
0x3F CellVoltage1
17.41 0x4C DynamicPower()
The bq78350-R1 includes the read-only DynamicPower() word command, which returns a value of
Current() × Voltage() in 10 mW units. If Current() and/or Voltage() are scaled, then the units of
DynamicPower() are also scaled.
SBS Cmd Mode Name Format
Size in
Bytes
Min Max Default Unit
0x4C R
Dynamic
Power
Integer 2 –32768 32767 — 10 mW
17.42 0x4D ExtAveCellVoltage()
This read-word function returns the external average cell voltage measurement, if enabled, which can be
used within the gas gauging algorithm for EDV2, EDV1, and EDV0 detection.
SBS Cmd Mode Name Format
Size in
Bytes
Min Max Default Unit
0x4D R
ExtAveCell
Voltage
Unsigned
Integer
2 0 65535 — mV
17.43 0x4E PendingEDV()
This read-word function returns the predicted EDV2 until EDV2 is reached, then the predicted EDV1 until
EDV1 is reached, and then the predicted EDV0. The format is Little Endian.
SBS Cmd Mode Name Format
Size in
Bytes
Min Max Default Unit
0x4E R PendingEDV
Unsigned
Integer
2 0 65535 — mV