0x4F StateOfHealth (SOH)
www.ti.com
138
SLUUBD3DSeptember 2015Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
17.44 0x4F StateOfHealth (SOH)
This command returns the state-of-health (SOH) information of the battery. StateOfHealth() is calculated
as a percentage of FullChargeCapacity() Design Capacity or Design Energy. It is a read-only command.
Byte 0: LSB of SOH in capacity
Byte 1: MSB of SOH in capacity
Byte 2: LSB of SOH in energy
Byte 3: MSB of SOH in energy
17.45 0x50 SafetyAlert
This command returns the SafetyAlert() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x50 SafetyAlert() R R Block H4
0x00000
000
0xFFFF
FFFF
17.46 0x51 SafetyStatus
This command returns the SafetyStatus() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x51 SafetyStatus() R R Block H4
0x00000
000
0xFFFF
FFFF
17.47 0x52 PFAlert
This command returns the PFAlert() flags. For a description of each bit flag, see the ManufacturerAccess()
version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x52 PFAlert() R R Block H4
0x00000
000
0xFFFF
FFFF
17.48 0x53 PFStatus
This command returns the PFStatus() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.
SBS
Cmd
Name
Access
Protocol Type Min Max Default Unit Note
SE US FA
0x53 PFStatus() R R Block H4
0x00000
000
0xFFFF
FFFF
17.49 0x54 OperationStatus
This command returns the OperationStatus() flags. For a description of each bit flag, see the
ManufacturerAccess() version of the same command in Section 17.2.

Table of Contents

Other manuals for Texas Instruments bq78350-R1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments bq78350-R1 and is the answer not in the manual?

Texas Instruments bq78350-R1 Specifications

General IconGeneral
BrandTexas Instruments
Modelbq78350-R1
CategoryController
LanguageEnglish

Related product manuals