Basic Configuration Options
www.ti.com
16
SLUUBD3D–September 2015–Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
Basic Measurement System
The bq78350-R1 determines which companion AFE is connected by the total number of cells connected.
• When Series Cells = 3 to 5, the bq76920 companion AFE is used.
• When Series Cells = 6 to 10, the bq76930 companion AFE is used.
• When Series Cells = 9 to 15, the bq76940 companion AFE is used.