Chapter 26 2. Functionally check baggage compartment smoke detector.
Chapter 67 3. Synchronized elevator:
a. Remove left and right elevators.
b. Clean elevator spars and inspect for corrosion.
c. Clean internal bore of elevator horn and inspect for
corrosion.
d. With elevator control removed, attach a spring scale to
hole in arm of horn where control tube is normally installed. Pull
scale at right angle to arm, verify friction is 26 to 32 pounds
(115.65 to 142.34 N). If friction is not within limits, adjust shim
thickness.
e. Install left and right elevators.
SCHEDULED INSPECTIONS
5-14. 600 HOURS/12 MONTHS — PART B (CONT)
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
26 JUN 2013 Rev. 14 Page 97/98