BHT-212-MM-1
5-00-00
Export Classification C, ECCN EAR99
5-20. FIN SPAR CAP INSPECTION EVERY 8 HOURS
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. _____________________
FACILITY: __________________________________________
HELICOPTER S/N: ___________________________________
REGISTRY NO.: _____________________________________
TOTAL TIME:_______________________________________
SIGNATURE:________________________________________
1. Accomplish inspection of fin spar caps P/N
212-030-125-001, 212-030-447-001 and 212-030-447-101
every 8 flight hours.
2. This special inspection is not required if fin spar cap P/N
212-030-447-117 has been installed as original equipment or in
accordance with TB 212-00-184.
3. Fin spar cap P/N 212-030-447-117 can be identified by the
presence of decals that identify the cold-worked holes.
FIN SPAR CAP 212-030-125-001 AND 212-030-447-001/101
ASB 212-00-110 1. Carry out 8 hour recurring inspection in accordance with
applicable section of ASB 212-00-110.
2. Any discrepancies (cracks, corrosion, debonding, or other
damage) are to be reported to Product Support Engineering
before further flight.
26 JUN 2013 Rev. 14 Page 117/118