5-32. EACH 150 HOURS OF STARTER GENERATOR P/N 200SG119Q OPERATION
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. _____________________
FACILITY: __________________________________________
HELICOPTER S/N: ___________________________________
REGISTRY NO.: _____________________________________
TOTAL TIME:_______________________________________
SIGNATURE:________________________________________
NOTE
Accomplish each 150 hours of starter generator P/N
200SG119Q operation or more frequently if
conditions warrant.
P/N 200SG119Q refers to the starter generator
without the QAD kit consisting of the mounting flange
and ring clamp.
This special inspection is not applicable to starter
generator P/N 209-060-221-001.
Chapter 71 1. Remove starter generator P/N 200SG119Q.
2. Inspect starter generator brushes for wear.
TM106 – Aircraft Parts
Corp. Overhaul
Instructions with
Illustrated Parts
Breakdown
3. If brushes are worn beyond allowable limits, refer to vendor
manual and replace in accordance with manufacturer’s
instructions.
4. Install starter generator.