EasyManua.ls Logo

Textron Bell 212 - 5-35 A. EACH 300 HOURS;12 MONTHS INSPECTION OF TAIL ROTOR CONTROL TUBE AND BEARING

Textron Bell 212
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BHT-212-MM-1
5-00-00
Export Classification C, ECCN EAR99
SPECIAL INSPECTIONS
5-35A. EACH 300 HOURS/12 MONTHS INSPECTION OF TAIL ROTOR CONTROL TUBE AND
BEARING
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. _____________________
FACILITY: __________________________________________
HELICOPTER S/N: ___________________________________
REGISTRY NO.: _____________________________________
TOTAL TIME:_______________________________________
SIGNATURE:________________________________________
NOTE
Accomplish each 300 flight hours or 12 months,
whichever occurs first.
ASB 212-15-154 TAIL ROTOR CONTROL TUBE 212-001-055-101 AND
BEARING DAS4-14A1-512
Chapter 67 1. Gain access to the tail rotor control tube P/N
212-001-055-101 and bellcranks P/N 212-001-705-001 and P/N
212-001-759-101.
2. Disconnect both ends of the tail rotor control tube P/N
212-001-055-101 from the corresponding bellcranks.
3. Without removing the tail rotor control tube, visually inspect
the flight control tube P/N 212-001-055-101 for cracks. If a crack
is found, remove the tube from service.
4. Inspect both bearings P/N DAS4-14A1-512 for freedom of
movement. Bearings shall be free to move in all directions and
rotate freely. If a defective bearing is found, replace the
defective bearing in accordance with the BHT-ALL-SPM.
5. Re-connect the tail rotor control tube in accordance with
Chapter 67.
15 NOV 2018 Rev. 16 Page 152A/152B