Loading...
BHT-212-MM-1
5-00-00
26 JUN 2013 Rev. 14 Page 25
Export Classification C, ECCN EAR99
WARNING
CAUSE OF ANY DISCOLORATION SHALL BE
DETERMINED AND CORRECTED PRIOR TO NEXT
FLIGHT.
2. Input quill flexible coupling and surrounding area for grease
leakage, damage, corrosion, and evidence of overheat as
indicated by TEMP-PLATES or coupling discoloration. A change
in color of one or more of the red bordered TEMP-PLATE dots
from white/off-white to black indicates an overheat condition and
may require replacement of both outer and inner couplings.
3. Overheat TEMP-PLATES for condition and security.
TEMP-PLATES must not show evidence of overtemperature
indication, deterioration, debonding, or excessive discoloration of
the epoxy overcoating.
4. Gearbox for proper oil level and oil for evidence of
contamination.
Chapter 67 ELEVATORS
— Detailed Visual Inspection
1. Elevators for damage and security.
Chapter 71 LEFT POWER SECTION
— Detailed Visual Inspection
1. Gas generator case for cracks, buckled areas, and hot
spots.
2. Oil and fuel hoses and tubes for chafing, leaking, and
security.
3. Electrical wiring for fraying, chafing, and security.
SCHEDULED INSPECTIONS
5-8. DAILY INSPECTION — PART A (CONT)
DATA
REFERENCE
INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER