en-73
MAINTENANCE AND LUBRICATION 7
8.12 BATTERY ____________________________________________________________
Before you service the battery, make sure the ignition switch is in the OFF position and the key is removed.
Keep the battery terminals tight, To prevent corrosion, apply a layer of silicone dielectric grease to battery
terminals and ends of cables. Keep the vent caps and
battery terminal covers in position.
Before welding any part on the Mower, disconnect the
battery cables and connectors from the controllers and
visual display unit.
Battery Access
1. Loosen and remove hand wheels (A) holding
engine cover sealing plate and remove engine cover sealing plate.
2. Loosen hand wheels (B) holding battery cover and remove battery cover.
Confirm the battery polarity before you connect or you disconnect the battery cables.
When you remove the battery, always disconnect the negative (BLACK) battery cable before the positive (RED)
battery cable.
When you install the battery, always connect the positive (RED) battery cable before the negative (BLACK)
battery cable.
Flat Battery Start
a Before you try to start the mower, check the condition of the drained battery.
b Connect the positive (+) battery terminal of the charged battery to positive battery terminal of the drained
battery.
c Connect the negative (–) battery terminal of the charged battery to frame of vehicle with the drained
battery.
d Connect the battery cables, start the engine on the vehicle with the good battery, then start the mower.
CAUTION
When you service the battery, use correctly insulated tools. Wear applicable eye protection and
clothing. Discard used batteries as shown in your local regulations.
WARNING
The battery contains corrosive acid. Prevent any contact with the battery acid.
Always Wash the Hands after you service a Battery.
WARNING
The battery posts, terminals and related parts contain lead and lead compounds. The State of
California understands Lead to be a cause of cancer and reproductive harm.
WARNING
The battery can release hydrogen gas that is explosive. Work in an area with good ventilation and
shield from any type of ignition. Always connect the negative jumper cable to the frame of the mower
with the drained battery.