AS 680/682
Description, Operation and Maintenance System Description
ADS−B
1−5Ed. 10.07
1.3 TECHNICAL CHARACTERISTICS
1.3.1 Dimensions and Weight
AS 680 basic system
SPU (HxWxD); weight 19", 3HU; 133x482x250 mm; approx. 7.1 kg
SM (HxWxD); weight 19", 1HU; 43x482x250 mm; approx. 1.0 kg
AS 682 cabinet, fully equipped, (HxWxD); weight 19", 24HU; 1200x600x600 mm; approx. 150 kg
− SPU (HxWxD); weight (2x) 19", 3HU;133x482x250 mm; approx. 7.1 kg
− SM (HxWxD)/weight 19", 1HU; 43x482x250 mm; approx. 1.0 kg
− Data Switch (HxWxD); weight 19", 1HU; 43x482x180 mm; approx. 1.5 kg
− UPS, basic (HxWxD); weight (2x) 19", 2HU; 86x444x410 mm; approx. 19 kg
− UPS, extension (HxWxD); weight (2x) 19", 2HU; 86x444x410 mm; approx. 25 kg
1.3.2 Peripheral Equipment
RX antenna, omnidirectional (H,∅); weight max. 3420 mm, 60 mm; approx. 26 kg max.
Antenna Amplifier Unit (AAU) (HxWxD); weight 280x180x105 mm; approx. 4 kg
AAU support and cover (HxWxD); weight 300x255x220; approx. 5 kg
GPS antenna, (HxW); weight (2x) 60x100 mm; approx. 0.3 kg
1.3.3 Power Supply
SPU
AC voltage input (AC/DC converter option) 100 to 240 VAC, 50/60 Hz, single phase
DC voltage input (DC/DC converter option) nom. 24 VDC, 18 to 36 VDC, max. 4.5 A
Power consumption approx. 55 VA
Site Monitor
AC voltage input via plug−in mains supply 100 to 240 VAC, 50/60 Hz (DC out 24 V)
Power consumption approx. 5 VA
DC voltage input nom. 24 VDC, 20 to 28 VDC, max. 1 A
Data Switch
AC voltage input 100 to 240 VAC, 50/60 Hz, single phase
DC intern 5 V, max. 8 A
UPS type RS 1000 with 1 battery extension
AC voltage input / max. current 160 to 276 VAC, 50 Hz, single phase / 6.0 A
AC voltage output 208/220/230/240 VAC / 50 Hz
Power rating approx. 1000 VA (700 W)
Batteries 3x 12V, 7Ah
Battery extension 1
Typical battery time (battery mode) in [min] 53 (100 % load), 122 (50 % load)
1.3.4 Environmental Conditions
Ambient temperature
Operation indoor , +10 to +40 °C
(SPU, Data Switch, SM, UPS)
Operation outdoor equipment (antennas) −40 to +70 °C
Transport −55 to +70 °C
Relative humidity
indoor max. 90%, non condensing
outdoor max. 95% (−10 to +39 °C); max. 50% (40 to 70 °C)
non operation and transport up to 100 % with condensation