AS 680/682
Description, Operation and Maintenance Installation and Setup
ADS−B
3−1Ed. 10.07
CHAPTER 3
INSTALLATION AND SETUP
3.1 INSTALLATION
3.1.1 General
The installation of the ADS−B Ground Station AS 680/682 equipment and the RCMS equipment in
the ATC centers depends on local conditions. The equipment can be easily integrated in existing envi-
ronment (e.g. existing buildings on remote sites or an ATC supervisor room). This means that the
illustrations do not show a concrete mounting procedure but the interconnection of the individual sys-
tem items. Recommendations and installation requirements are listed in section 3.1.6. The difference
of AS 680 to AS 682 is that the AS 680 consists of individual equipment to be integrated by the cus-
tomer while the AS 682 is a redundant equipped station already assembleded in a 19" cabinet.
The environmental conditions, preparations and given technical facilities of the installation sites have
to be in accordance with the technical characteristics as described in chapter 1, section 1.3. Cables
indicated as 1) in Figs. 3−9 to 3−11 are provided by the customer. Also mounting facilities for equip-
ment and antenna or cable run are to be provided by the customer. Verification test procedures after
site installation and a related installation report form are described in section 3.6.
3.1.2 Hardware Items for Installation
3.1.2.1 Ground Station AS 680
The following table lists the hardware and software items of the ADS−B Ground Station AS 680.
Hardware Item P/N Remark
ADS−B Ground Station AS 680 comprises individual equipment
Signal Processing Unit DC/DC 83142 71030
− GTS DG14 83142 71600
− SBC 83142 71230
− SPB 83142 71301
− RXU2 83142 71503 Replaces RXU1, Ref.No. 83142 71502
− DC/DC converter 58142 30510
− DC kit 58142 30610
− Fan Unit 58142 30400
− Dust filter mat 58142 30410
Signal Processing Unit, AC/DC option 83142 71020 used if mains supply is provided
− AC/DC converter 58142 30500
− AC kit 58142 30600
Option: Mounting kit for 19" rack 22731 28001 consists of 4 screws, 4 washers, 4 cage nuts
Option: Exchange panel 35490 28061 used to interconnect RF cables
Site Monitor 61460054
GPS Antenna 72600 28001 incl. adapter
Option: mounting kit for GPS antenna 58142 50020 incl. mounting tube 34450 28021, 2 clamps
ADS−B RX Antenna 97980 28192
Option: Mounting frame for antennas xxxxx xxxxx used individually for antenna mounting on site
AAU (ADS−B Antenna Amplifier Unit) 83142 75100 incl. LNA unit, mounting kit, weather protection
− LNA−Unit incl. housing 83142 75210 incl.lightning protection of RF IN, RF filter
− LNA−Unit incl. housing 83142 75310 incl.lightning prot. of RF IN, RFfilter, input limiter
− LNA−housing mast support (mounting kit) 35380 28051
Cable set ADS−B (optional) 58142 40020 Refer to 3.1.4.