Page #25 background imageLoading...
Page #25 background image
20 | Operation Ultra Low Temperature Freezers
Support: Press this button to view the service contact
information.
User Manual: QR Code/Link to download the user
manual.
Warranty Registration: QR code / Link to perform
warranty registration.
Configuration Files: This is used to export or import
configuration files. Configuration files may be uploaded to
other freezers. A passphrase will be required to export or
import configuration files.
Note: The imported setpoint and offset must be verified by
the user after the import.
Factory Reset: Select to reset the settings, including
temperature setpoint to factory defaults. This is the only
method to change the Access Mode.
Event Log
The third tab on the navigation panel is the event log that
contains a record of user and system events. The Event Log
screen will be displayed once the Event Log icon is pressed.
This screen displays up to 2 weeks of recent events with date
time stamps for each event.
The Date/Time and Event columns can be sorted in an
ascending or descending order by selecting the column
header.
Figure 27. Event Log Screen
Additional information of an individual event can be viewed by
selecting the event.
There is a drop-down list based on the event types. The event
types can be filtered and categorized into: Warning, Door,
User, Battery, and Backup. When a filter is selected, the View
All button on the right changes to Filter ON.
Figure 28. Event Log Screen with Filter
Press the Export Log button to export system data to a USB
drive. Refer to Reports for details.
Warnings
By selecting the warning tab, the Warning Settings screen is
displayed. For more information on setpoints, refer to
Warnings.
Figure 29. Warning Settings Screen
Users
The User tab is used to display the Users screen. This screen
is only accessible in Secure Mode. Use this screen add to a
user to the system or import and/or export the user database.
The following screen is displayed when the User icon is
selected:

Table of Contents

Other manuals for Thermo Scientific TSX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific TSX Series and is the answer not in the manual?

Thermo Scientific TSX Series Specifications

General IconGeneral
TypeLaboratory Refrigerator
Cooling TypeForced air cooling
Defrost TypeAutomatic
Door TypeSolid or glass door options
Controller TypeMicroprocessor
Certifications/ComplianceUL, CE
Energy ConsumptionVaries by model; refer to product specification sheet
Voltage115V
Exterior Dimensions (H x W x D)Varies by model; refer to product specification sheet
Interior Dimensions (H x W x D)Varies by model; refer to product specification sheet
WeightVaries by model; refer to product specification sheet
ShelvesAdjustable shelves
Energy EfficiencyEnergy Star certified models available