© 2013 Thorlabs GmbH236
DCx Cameras
4.3.37 is_GetColorConverter
USB 2.0
USB 3.0
USB 2.0
USB 3.0
Syntax
INT is_GetColorConverter (HIDS hCam,
INT ColorMode,
INT* pCurrentConvertMode,
INT* pDefaultConvertMode,
INT* pSupportedConvertModes)
Description
For color cameras, is_GetColorConverter() returns the set mode or all available Bayer conversion modes for
the specified color mode. The return value depends on the selected color mode. For further information, please
refer to the Appendix: color and memory formats section.
Input parameters
hCam
Camera handle
ColorMode
Color mode for which the converter is to be returned
For a list of all available color formats and the associated
input parameters, see the Appendix: Color and memory
formats section.
pCurrentConvertMode
Currently selected converter for this color mode
pDefaultConvertMode
Default converter for this color mode
pSupportedConvertModes
All converters supported for this color mode. Possible
converters are:
IS_CONV_MODE_NONE
IS_CONV_MODE_SOFTWARE_3X3
IS_CONV_MODE_SOFTWARE_5X5
IS_CONV_MODE_HARDWARE_3X3
Return values
IS_INVALID_COLOR_FORMAT
Invalid color format
IS_INVALID_CAMERA_HANDLE
Invalid camera handle
IS_NO_SUCCESS
General error message
IS_SUCCESS
Function executed successfully
Related functions
is_SetColorConverter()
is_SetColorMode()
502
502
315
319

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals